info@i2iinc.in
+91-96748 97316
Home
>
Our Products
>
Product Details
We Deal With
our products____________

Fire Detection, Alarm & Suppression Systems
FIRE HYDRANT SYSTEM

We understand the importance of Safeguarding Lives and Property against the devastating effects of Fires. That's why we offer top-of-the-line Fire Hydrant Systems, designed to provide Reliable Fire Protection for Residential, Commercial, and Industrial Properties. Our Fire Hydrant Systems are meticulously engineered to meet the Highest Safety Standards and deliver a readily available water supply for Firefighting Purposes. Our Fire Hydrant Systems ensure quick access to a dedicated water supply & deliver high water flow rates, enabling Firefighters to extinguish Fires effectively. Our Fire Hydrant Systems can be seamlessly integrated with other Fire Safety Systems, such as Fire Sprinklers, Fire Alarms, and Smoke Detection Systems. This integration ensures a comprehensive and interconnected Fire Protection Network, Enabling Early Detection, Alerting Occupants, and initiating the appropriate response in case of a Fire Emergency. We provide High-Quality Materials that withstand the test of Time and Harsh Environmental Conditions, ensures that all components are installed correctly and undergo rigorous testing to guarantee their reliability. We understand that every property is unique, and Fire Protection requirements may vary for which Our Team of Experts will work closely with you to design a Fire Hydrant System specific to your needs keeping adherence to the Local Fire Safety Regulations and Standards. Our Expert Team is ready to guide you through the Process, Providing Customized Solutions, Professional Installation, and Ongoing Support.

Types of Hydrant Systems____________

Wet Riser Fire Hydrant System

A Wet Riser Fire Hydrant System is a type of fire protection system commonly used in high-rise buildings or large structures. It is designed to provide a continuous pressurized water supply to firefighters for effective fire suppression. The wet riser system comprises a network of pipes always filled with water, allowing immediate access to water when needed. These systems must comply with local fire safety codes and regulations, which may include requirements for system design, installation, flow rates, and accessibility. Here's how a wet riser fire hydrant system typically works:

1. Water Source: The system is connected to a reliable water source, such as a dedicated water tank or the municipal water supply. The water source must have sufficient capacity to meet the demands of firefighting operations.

2. Riser Pipes: The system includes vertical riser pipes that run throughout the building, usually in stairwells or dedicated riser shafts. These riser pipes are filled with water under pressure and are connected to the water source.

3. Hydrants and Landing Valves: At designated intervals, the riser pipes are equipped with fire hydrants or landing valves. These fixtures provide access points for firefighters to connect their hoses.

4. Pressure Control & Water Distribution: The wet riser system incorporates pressure control devices to maintain adequate water pressure throughout the system. Once the hoses are connected, water flows from the wet riser system through the hoses to the firefighting area.

5. Fire Hose Connections: When a fire occurs, firefighters connect their hoses to the hydrants or landing valves to access the pressurized water supply. The hoses are typically stored in cabinets or hose reels located on each floor, ensuring quick deployment.

Types of Hydrant Systems____________

Dry Riser Fire Hydrant System

A Dry Riser Fire Hydrant System is a type of fire protection system commonly used in buildings where a constant water supply is not available within the internal piping network. It is particularly suitable for buildings under construction or buildings with intermittent water supply. The dry riser system allows firefighters to quickly connect to an external water source and deliver water to higher levels of the building. Here's how a dry riser fire hydrant system typically works:

1. Riser Pipes: The dry riser system consists of vertical riser pipes that run throughout the building, usually in stairwells or dedicated riser shafts. Unlike wet riser systems, the pipes in a dry riser system remain dry and empty when not in use.

2. Inlet Connection: The system has an inlet connection, usually located at the ground level, where firefighters can connect an external water supply source. This can be a fire engine, fire hydrant, or a dedicated water pump.

3. Landing Valves: At designated intervals, the dry riser pipes are equipped with landing valves. These valves are usually enclosed in cabinets or recessed outlets and are used as connection points for firefighting hoses.

4. Fire Hose Connections: When a fire occurs, firefighters connect their hoses to the landing valves on the dry riser system. The hoses are typically stored in cabinets or hose reels located on each floor for easy access.

5. Water Distribution: Once the firefighting hoses are connected, water is supplied from the external source through the dry riser system to the firefighting area. Firefighters use various nozzles attached to the hoses to control the water flow and direct it towards the fire for suppression.

6. Pressure Maintenance: To ensure adequate water pressure within the dry riser system, pressure-maintenance devices such as air release valves, pressure-reducing valves, and pressure gauges may be installed. These devices help regulate and monitor the water pressure during firefighting operations.

COMPONENTS OF FIRE HYDRANT SYSTEM____________

Firefighting Pump, Panels & Accessories

Fire hydrant systems consist of various components that work together to provide a reliable water supply for firefighting purposes. The components of a fire hydrant system include:

1. Firefighting Pumps and Accessories: The pumps that supply water pressure to the fire hydrant system are known as firefighting pumps and accessories. They come in various sizes and capacities and can be either electrically or diesel-powered. Extras include relief valves, pressure switches, and pressure gauges.

2. Panels: The panels act as the fire hydrant system's command centre. The control valves are housed there, along with other crucial parts, including flow meter's, pressure switches, and alarms.

3. Piping: The network of pipes known as "piping" transports water from a source to a system of fire hydrants. They are typically manufactured of sturdy materials like ductile iron or galvanized steel to endure high pressures.

4. Landing Valves: The primary control valves for the fire hydrant system are the landing valves. They typically stand close to the building's entrance and provide firemen access to the system's water supply.

5. Couplings: The connectors that connect the various components of the fire hydrant system are known as couplings. Firefighters can quickly attach hoses and other parts thanks to their quick and simple connect and disengage designs.

Components of Fire Hydrant System____________

Hoses, Hose Reels, Branch Pipe & Nozzels

Fire hydrant systems consist of various components that work together to provide a reliable water supply for firefighting purposes. The components of a fire hydrant system include:

1. Hoses & Hose Reels: Firefighters utilise hoses, which are pliable pipes, to send water towards the flames. They are built of strong materials like synthetic rubber or PVC and are available in various lengths and sizes. Hose Reel is a tool that keeps hoses in storage and releases them as needed. It is often accessible and close to the fire hydrant system's control panel.

2. Fire Brigade Connections: Firefighters can attach their hoses to the fire hydrant system at fire brigade connections. They often come with a landing valve and a coupler to make connections quick and simple.

3. Branch Pipes and Nozzles: Firefighters use branch pipes and nozzles to steer water towards the flames. Depending on the purpose, they are available in various sizes and varieties.

4.Wiring & Instrumentation: These are the components that make it possible to monitor and manage the fire hydrant system. They consist of flow meter's, pressure valves, and alarms that notify firemen of systemic issues.

5. Maintenance Valves: To isolate specific components of the fire hydrant system for maintenance or repair, utilize a maintenance valve. They often stand at key intersections along the system, allowing firefighters to service it without interfering with its normal operation.

Our products_______

Get the Best
Products from Us

Fire Detection, Alarm & Suppression Systems

I2I Inc is committed to deliver High-Quality Fire Detection, Alarm, and Suppression Systems that meet Industry Standards & Regulations. Installing Fire Detection, Alarm, & Suppression Systems is one of the most important things you can do to ensure the Safety of your Workplace. Our Experienced Team of Professionals will work closely with you to assess your specific needs, design tailored solutions, & provide ongoing Maintenance & Support.

Customized Signage & Posters Printing

I2I Inc Design and Print a range of High-Quality Signboards and Posters that can effectively convey important information to your Employees and Clients. Workplace Signboards and Posters can help you achieve a variety of goals, including Safety Compliance, Brand Awareness, and Employee Engagement. Our Signboards are fully customizable, allowing you to choose from a Variety of Materials, Sizes, Shapes, and Finishing Options.

Personal Protective Equipment

I2I Inc provides High-Quality Personal Protective Equipment to different Industries. Workplace Safety is a top priority, & our range of PPE products is designed to Protect Employees’ Health & Safety while on the job. We can assess your Workplace to determine your PPE needs & recommend the right products that will protect your employees from Hazards & Injuries. Our Team of Experts can help you choose the right PPE Products that meet your specific Safety Requirements.

Surveillance Systems

I2I Inc provides High-Quality Surveillance Systems to businesses across Different Industries. We have Years of Experience in Designing, Installing, and Maintaining Surveillance Systems in Factories and Offices. Our Surveillance Systems help you keep an eye on your Premises, Employees, and Valuable Assets, ensuring that you have Complete Control and Surveillance Over Your Operations. Our Systems also help improve Workplace Safety.

Attendance Systems

We understand the Importance of Tracking Employee Attendance, Maintaining Accurate Records and Payroll Processing. By automating the Attendance Tracking Process, Businesses can eliminate Manual Errors, Improve Accuracy, and Save Valuable Time and Resources. Our Attendance Systems provide real-time data, enabling Businesses to make Informed Decisions, Optimize Scheduling, and Ensure Compliance with Labor Regulations.

Emergency Equipment

Emergency Equipment aim to reduce the effect of destruction caused by unexpected situations like Accidents, Fire, Sabotage, Spills, Explosions, Natural Disasters, Terrorist Activities and Medical Emergencies. I2I Inc specializes in providing a wide range of Essential Equipment designed Enhance Safety, provide Critical Resources, and Ensure Readiness in times of Crisis to help Individuals, Businesses, and Communities to respond to Emergency Situations.